DISCONNECT AND LOCKOUT

ELECTRICAL POWER BEFORE AT-

TEMPTING ANY MAINTENANCE.

FAILURE TO DO SO CAN CAUSE

SHOCK, BURNS OR DEATH.

SYMPTOM
MOTOR NOT RUNNING

See Probable Cause – 1 through 5

LITTLE OR NO LIQUID DELIVERED BY PUMP

See Probable Cause – 6 through 1

POWER CONSUMPTION TOO HIGH

See Probable Cause – 3, 1, 13, 15

EXCESSIVE NOISE AND VIBRATION

See Probable Cause – 3, 6 - 8, 10, 1, 13, 16

PROBABLE CAUSE
1. Motor thermal protector tripped.
2. Open circuit breaker or blown fuse.
3. Impellers binding.
4. Motor improperly wired.
5. Defective motor.
6. Pump is not primed, air or gases in liquid.
7. Discharge, suction plugged or valve closed.
8. Incorrect rotation (three phase only).
9. Low voltage or phase loss.
10. Impellers worn or plugged.
11. System head too high.
12. NPSHA too low – excessive suction lift or losses.
13. Discharge head too low – excessive flow rate.
14. Fluid viscosity, specific gravity too high.
15. Worn bearing.
16. Pump, motor or piping loose.

Maximum Working Pressure =

(1SV, SV, 3SV, SV)

30 psi (16 bar) with the oval suction and

discharge flanges

360 psi (5 bar) with ANSI suction and

discharge flanges

Maximum Liquid Temperature =

30º F (110º C)

STARTS PER HOUR / MINIMUM RUN TIME – 3 Phase Only

HP

maximum Starts Per Hour

minimum Run Time Between

(evenly distributed)

Starts (seconds)

1

15

75

1.5

13

76

2

12

77

3

9

80

5

8

83

7.5

7

88

10

6

92

15

5

100

20

5

110

25

5

115

30

4

120

40

4

130

50

3

145

60

3

170

75

3

180

NoTE(S)
1) Recommended motor starts per hour and minimum run time calculated based on

NEMA standards MG1-12.44 in accordance to manufacturers allowable tolerance
for heat rise and insulation breakdown.

2) Applied voltage and frequency in accordance with NEMA MG1-12.44
3) Starts based on NEMA three phase design A and design B AC induction motors.
4) External load WK2 is equal to or less than the values listed in NEMA MG1-12.54
5) Applicable to all NEMA JM, JP, T and TC frame motors used for Goulds Pumps

products.

6) SINGLE PHASE starts and run time depend on many factors (e.g. capacitor size/

type, wire size and length, switch type) and will not be the same as three phase
motors.