Technical data

7 - 1

ba76129e01

10/2012

7

Technical data

7.1

Measurement characteristics

Measuring principle

Ultrasound echo measurement

Measuring ranges and

resolution

Conversion to sludge level depth (from the surface of the water) or
sludge level height (from the bottom of the basin)

7.2

Application characteristics

Allowed

temperature range

Allowed pH range of the

measuring medium

4 ... 12

Pressure resistance

Sensor with connected SACIQ (SW) sensor connection cable:

Type of protection

Sensor with connected SACIQ (SW) sensor connection cable:
IP X8; 0.3 bar (3*10

5

Pa)

Immersion depth

min. 5 cm; max. 3 m

Flow speed

max. 3 m/s

Operating position

Vertical with ultrasonic transducer pointing downward

Measured
parameter

Measuring ranges

Resolution

Accuracy

Distance

0.4 ... 15 m from
ultrasonic trans-
ducer surface

0.01 m

0.1 m

Measuring medium

0 °C ... + 50 °C (32 ... 122°F)

Storage/transport

- 5 °C ... + 50 °C (23 ... 122 °F)

Max. allowed overpressure:

3*10

5

Pa (0.3 bar)