IFL 70x IQ

What to do if...

6 - 3

ba76129e01

10/2012

Number and position of

the echoes changing

often

Intensity of the existing

echoes changing

Cause

Remedy

Small temporary interfering
echoes

(e.g. sludge flakes sinking slowly)

– Check Echo selection (Top-

most echo or Strongest
echo
)

– A higher value for the Mini-

mum intensity filter ignores
echoes from small, slowly
sinking sludge fields.

New sludge blankets developing

(e.g. a new sludge blanket devel-
oping on top of an old, concen-
trated sludge blanket).

– Check Echo selection (Top-

most echo or Strongest
echo
)

Follow echo

(change setting to Yes)

– Set the Evaluation range to

the range expected for the
sludge level

Cause

Remedy

Temporary effect of air bubbles or
thread algae

– Select a measurement loca-

tion that has permanently
few air bubbles.

– Remove any thread algae

from the sensor and its envi-
ronment

– Clean the sensor

Check the wiper

– Check Echo selection (Top-

most echo or Strongest
echo
)

Follow echo

(change setting to Yes)

– Set the Evaluation range to

the range expected for the
sludge level

The sludge blanket level is very
high, or the sedimentation behav-
ior is insufficient

Check and adjust the process