8 indexes, 1 explanation of the messages, 1 error messages – YSI IFL 700 IQ User Manual

Page 39: Indexes -1, Explanation of the messages -1 8.1.1, Error messages -1, 8indexes

Advertising
background image

IFL 70x IQ

Indexes

8 - 1

ba76129e01

10/2012

8

Indexes

8.1

Explanation of the messages

This chapter contains a list of all the message codes and related mes-
sage texts that can occur in the log book of the IQ S

ENSOR

N

ET

system

for the IFL 70x IQ sensor.

Information on the contents and structure of the log book and the struc-

ture of the message code is given in the L

OG

BOOK

chapter of the

IQ S

ENSOR

N

ET

system operating manual.

The last three digits of the message code form the component code. It

identifies the component (active component) that caused the message:
Some error messages contain an internal error code, starting with "#".

8.1.1 Error messages

Module code

Component

3C1

IFL 700 IQ

3C2

IFL 701 IQ

Message code

Message text

EI13Cx

Operational voltage too low
* Check installation and cable lengths, Follow installation instructions
* Power supply module(s) overloaded, add power supply module(s)
* Check terminal and module connections
* Defective components, replace components

EI23Cx

Operational voltage too low, no operation possible
* Check installation and cable lengths, Follow installation instructions
* Power supply module(s) overloaded, add power supply module(s)
* Check terminal and module connections
* Defective components,
replace components

ES13Cx

Component hardware defective
* Contact service

ESA3Cx

No sludge level can be determined in the selected evaluation range
* Clean and immerse the sensor
* Check all settings, especially for immersion depth, water depth, val-
ues to be ignored

ESB3Cx

Erroneous sensor position
* Check the sensor fixations and fix the sensor in a vertical measuring
position