A-100nv, Mode 4 programming examples, Page 15 – Xylem A-100NV DIGITAL PERISTALTIC PUMPS User Manual

Page 15: 4mode

Advertising
background image

PROGRAM MODE 4

minimum input value

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

4

MODE

620

Hz

currently programmed maximum motor speed value is
shown on the 3-DIGIT LCD.

4 Enter the motor speed at the maximum VDC input

signal value. Press the FIELD button to select the
digit to program. The digit will blink when selected.

4 Press the DIGIT button to change the selected digit.

4 Repeat until all digits are programmed.

4 Press the mode button. The % SPEED icon will stop

blinking and the Hz icon will blink indicating the
maximum Hz value is ready to be programmed. The
currently programmed maximum value is shown on
the 3-DIGIT LCD.

4 Enter the maximum Hz input signal value (to the

nearest 10 Hz). Note: this value must be greater than
the minimum Hz input signal value. Press the FIELD
button to select the digit to program. The digit will
blink when selected.

4 Press the DIGIT button to change the selected digit.

4 Repeat until all digits are programmed.

4 Press the mode button. Programming is complete.

4 To exit the programming mode, press the

RUN/STANDBY button and the MODE button at the
same time. The PROGRAM arrow will disappear.

PROGRAM MODE 4

% speed at the maximum input

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

% SPEED

4

MODE

82.5

MODE 4 PROGRAMMING EXAMPLES

Example 1

0

200 400 600 800 1000

0

25

50

75

100

Pump

M

otor

S

p

eed

(%)

Frequency input (Hz)

0 Hz = 0% OUTPUT

1000 Hz = 100% OUTPUT

Example 2

0

200 400 600 800 1000

0

25

50

75

100

Pump

Motor

S

p

eed

(%)

Frequency input (Hz)

0 Hz = 100% OUTPUT

1000 Hz = 0% OUTPUT

Example 3

0

200 400 600 800 1000

0

25

50

75

100

Pump

Motor

S

peed

(%)

Frequency input (Hz)

0 Hz = 10% OUTPUT

270 Hz = 75% OUTPUT