A-100nv, Circuit board connections, Page 7 – Xylem A-100NV DIGITAL PERISTALTIC PUMPS User Manual

Page 7

Advertising
background image

Page 7

CIRCUIT BOARD CONNECTIONS

AC sine waves

Jumper Not Installed

(open - factory default)

Digital square waves

Jumper Installed

DC

MOTOR

BLACK (-)

RED (+)

Ground (green)

Earth Ground (green)

Common

Hot

AC

Input

Power

PROTECTOR FUSE

1 Amp, 250 Volt AC

(Littlefuse #239001

or Equivalent)

1 AMP

250VAC

MOTOR

RED (+)

MOTOR

BLACK (-)

AC LINE

NEUTRAL

AC LINE

HOT

TS

THERMAL SWITCH

.187 push tab connectors

2 conductors

11

0

11

0

202

AC LINE VOLTAGE SETTINGS

230 VAC

One Jumper Installed

on center position

(ends open)

115 VAC

Two Jumpers Installed

on end positions

(no open pins)

BLUE (4-20 mA input)

BLACK (Ground)

YELLOW (verification sensor input)

ORANGE (0-10 VDC input)

RED (+20VDC)

WHITE (frequency input)

JUNCTION BOX

LIQUID-TIGHT
CONNECTOR

ACCEPTABLE CABLE JACKET RANGE:

.118 - .255 INCH
.(

3,0 - 6,5 MM)

EXTERNAL INPUT CABLE

BROWN (motor-on contact output)

INPUT SIGNAL CONNECTOR

7 wire bundle

Hz INPUT JUMPER SETTINGS

Located under connector

PR

BEO

CN

ON

ALARM OUTPUT

(CONTACT CLOSURE)

normally open (NO)

(factory default)

TUBE FAILURE SENSOR

PROBE INPUT

2 Grey wires pump head sensors.

PURPLE X2 (alarm relay contacts)

A-100NV

Advertising