A-100nv, 3 external input signal connections, Signal input/output wire color codes – Xylem A-100NV DIGITAL PERISTALTIC PUMPS User Manual

Page 6: Paddlewheel sensor signal input wiring, Page 6

Advertising
background image

Page 6

5.3 External Input Signal Connections

The A-100NV will accept any one of three different types of external input
signals; 4-20 mA , 0-10 VDC, or frequency. The 4-20mA and 0-10 VDC
loops must be powered. Two types of frequency inputs, AC sine waves
(magnetic coils type outputs) and Digital Square waves (Hall Effect signals,
contact closures), are acceptable. A jumper plug located on the circuit board
is factory pre-set for AC sine wave signals, the jumper must be re-
positioned when digital square wave signals are being used. See page 7,
“Hz input jumper settings”

All wiring connections are to be made inside of the junction box located on
the side of the A-100NV. A liquid-tite connector is supplied and should be
used for the external signal cable. The signal input wires are color coded to
the type of signal being used.

SIGNAL INPUT/OUTPUT WIRE COLOR CODES

WIRE COLOR CODE

INPUT TYPE

MOTOR ON SIGNAL

5-20V DC open collector output

closed while motor is energized

FLOW VERIFICATION SENSOR

4-20 mA

0-10 VDC

ALARM RELAY

connect 2-conductor plug to either

normally open (NO) (factory default)

or normally closed (NC) side of receptacle.

1 AMP MAX @ 125VAC (24VDC)

BROWN (+) & BLACK (-)

PURPLE & PURPLE

WHITE (+) & BLACK (-)

BLUE (+) (non-powered) & BLACK (-)

AC sine wave, TTL, CMOS

ORANGE (+) (non-powered) & BLACK (-)

RED/WHITE (+ 20VDC)

BLACK (-)

YELLOW (signal)

CONTACT (10v @ 2 mA max)

HALL EFFECT, NPN

RED (+) & WHITE (-)

A-100NV

PADDLEWHEEL SENSOR SIGNAL INPUT WIRING

PADDLEWHEEL SENSOR

WIRE COLOR CODE

BLUE-WHITE

PADDLEWHEEL

SENSOR TYPE

MODEL FH

HALL EFFECT SENSOR

BLACK (-)

RED (+)

PUMP INPUT

WIRE COLOR CODE

MODEL FC

AC SINE WAVE SENSOR

BARE (signal)

BLACK (-)

RED (+ 20VDC)

WHITE (signal)

BLACK (-)

RED (+)

BLACK (-)

WHITE (+)

Advertising