2.0 Specifications

Maximum Working Pressure

100 psig / 6.9 bar (most models)

o o

Maximum Fluid Temperature

130 F / 54 C

o o

Ambient Temperature Range

14 to 110 F / -10 to 43 C

Duty Cycle

Continuous

Maximum Solids

50% by volume

Maximum Viscosity

5,000 Centipoise

Maximum Suction Lift

up to 30 ft. water

Power Requirements

108/130Vac 60Hz 40 Watts,
208/250Vac 40Hz 40 Watts,
208/250Vac 60Hz 45 Watts

Dimensions

6-1/8” H x 10-1/8” W x 9” D

Weight

12 lb.

3.0 Features

!

Peristaltic Pump Tube does not require valves.

!

Self priming under maximum pressure. Cannot vapor lock.

!

High outlet pressure capability of 100 psig (most models).

!

High inlet suction lift capability of 30 feet.

!

Patented Tube Failure Detection (TFD) system.

!

Patented pump tube assembly design.

!

Includes Flow Verification System (FVS) - sensor sold separately.

!

1 amp alarm relay (dry contact).

!

Alarm and Service alert icon displays.

!

Corrosion proof Valox housing.

!

Tamper resistant electronic control panel cover.

4.0 Unpacking

Your pump package should contain the following:
1 - Injector pump with 2 pump tube assemblies
1 - suction tube strainer
1 - ceramic tubing weight
1 - 5’ Length of clear PVC suction tubing
1 - 5’ Length of opaque LLDPE discharge tubing
1 - Injection fitting with internal back-flow check valve
1 - Mounting hardware kit