Pump insulation checklist – Xylem P2001406B Series e-1510 Centrifugal Pumps User Manual

Page 17

Advertising
background image

Check

Explanation/comment

Checked

Check that the suction and discharge pipes are

supported independently by use of pipe hangers near

the pump .

This eliminates pipe strain on the pump .

Check that there is a strong, rigid support for the

suction and discharge lines.

As a rule, ordinary wire or band hangers are not

adequate to maintain proper alignment.

For pumps with flanges, check that the bolt holes in

the pump flanges match the bolt holes in the pipe

flanges.

Check that the suction or discharge lines are not

forced into position.

Coupling and bearing wear will result if suction

or discharge lines are forced into position.

Check that fittings for absorbing expansion are

installed in the system when considerable

temperature changes are expected.

This helps to avoid strain on the pump.

Check that you have a foot valve of equal or greater

area than the pump suction piping when you use in

an open system with a suction lift.

Prevent clogging by using a strainer at the

suction inlet next to the foot valve. Make sure

that the strainer has an area three times that of

the suction pipe with a mesh hole diameter of

no less than 0.25 in. (0.64 cm).

Check that flexible piping is used on both the suction

and discharge sides of the pump when you use an

isolation base.

Check that a B&G Triple Duty

®

valve is installed in the

discharge line.

This valve serves as a check valve that protects

the pump from water hammer, and serves as an

isolation valve for servicing and for throttling.

Check that the pipeline has isolation valves around

the pump and has a drain valve in the suction pipe.

Use PTFE tape sealer or a high quality thread sealant

when you install the suction and discharge

connections to a threaded pump housing.

Pump insulation checklist

Check

Checked

Check that the bearing assembly grease fittings are

accessible and visible.
Check that the vent slots on the sides and bottom of the

bearing assembly are uncovered and completely open.

Installation

Series e-1510 Installation, Operation, and Maintenance Manual

15

Advertising