NOTICE:

• Do not rotate the coupler to make adjustments. This may result in equipment

damage.

• Do not move or shim the driver unless you need to make adjustments. This may result

in decreased performance.

Make sure you have the following before you start this procedure:

• A micrometer or a caliper
• A maximum 1/64 in. (0.397 mm) end clearance between the sleeve and the two

coupling halves

1. Check for angular misalignment:

a) Measure from the outside face of one flange to the outside face of the opposite

flange at four points 90° apart. Use the micrometer or the caliper.
The maximum permitted reading value is 1/64 in. (0.397 mm) per inch of the
coupling radius.

1

1.

Distances Across Coupling Flanges Should Be Equal (check 4 places)

Figure 3: Example of angular misalignment

b) Move or shim the drive unit, if necessary, until the permitted reading value is

obtained.

2. Check for parallel misalignment:

a) Put a straight edge across one coupling half.
b) Measure the gap between the straight edge and the opposite coupling half. Use

the micrometer or the caliper.
A gap of maximum 1/64 in. (0.397 mm) is permitted.

Installation

Series e-1510 Installation, Operation, and Maintenance Manual

19