Assemble the single mechanical seal (e-1510-s) – Xylem P2001406B Series e-1510 Centrifugal Pumps User Manual

Page 33

Advertising
background image

2

1

3

4

5

6

7

8

9

11

13

14

16

17

18

10

12

15

1.

Impeller

2.

Vent Plug

3.

Volute

4.

Volute Gasket

5.

Coverplate

6.

Seal Assembly

7.

Bearing Frame

8.

Shaft

9.

Support Foot

10. Support Foot Capscrews

11. Slinger

12. Bearing Frame Capscrews

13. Shaft Sleeve

14. Impeller Key

15. Impeller Washer

16. Impeller Lock Washer

17. Drain Plug

18. Impeller Capscrew

Figure 7: 1510, 1510–F

Assemble the single mechanical seal (e-1510-S)
1. Lubricate the shaft sleeve and seal cap with soapy water.

Do not use a petroleum lubricant.

2. Insert a stationary seal with an O-ring into the seal cap and slide it onto the shaft.
3. Replace the seal cap gasket.
4. Slide the rotating portion of the seal assembly onto the shaft sleeve and lock it in

place.

ID seal size

Distance between collar and impeller end of the shaft sleeve

1-1/4 in. (3.175 cm)

1-13/32 in. (3.571 cm)

1-5/8 in. (4.128 cm)

1-1/4 in. (3.175 cm)

2-3/8 in. (6.033 cm)

1-1/4 in. (3.175 cm)

5. Assemble the coverplate onto the bracket.
6. Tighten the capscrews according to the Capscrew torque table.

Maintenance

Series e-1510 Installation, Operation, and Maintenance Manual

31