V. specifications, Dc: 12 to 30 vdc, 0.07 amps max. @ 24 vdc, Communication: optional rs232 or rs485 – Xylem WL900 RADAR LEVEL TRANSMITTERS User Manual

Page 5: Accuracy: ±0.25% of maximum sensor range (in air), Frequency: 6.3 ghz (or 5.8ghz ce), Resolution: 0.22in (5.7mm), Transmitter power: 50 uw average, Calibration: push-button or optional programmable, Antenna: polypropylene over dielectric rod, Beam angle: 12 degrees

Advertising
background image

Global Water

800-876-1172

globalw.com

- 5 -

V. Specifications

Power:

AC: 115 VAC, 60 Hz or 230 VAC, 50 Hz (± 20%), 1.7 VA

DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC

Outputs:

Signal: 4-20 mA, 6.1 uA resolution; 750 ohms

Communication: Optional RS232 or RS485

Accuracy:

±0.25% of maximum sensor range (in air)

Frequency:

6.3 GHz (or 5.8GHz CE)

Measurement Range: 10” to 50’ (0.254 meters to 15.2 meters)

Resolution:

0.22in (5.7mm)

Transmitter Power: 50 uW average

Calibration:

Push-button or optional programmable

Antenna:

Polypropylene over dielectric rod

Beam Angle:

12 degrees

Operating Temp: -40°C to 60°C (-40°F to 140°F)

Operating Pressure: 150 psi max

Installation Category: Class II

Process connection: 2” NPT

Conduit Entry:

1/2” NPT standard

Housing:

Aluminum or 316L stainless steel

Ingress Protection: NEMA 4 (IP65)

Advertising