Vi. operation – Xylem WL900 RADAR LEVEL TRANSMITTERS User Manual

Page 7

Advertising
background image

Global Water

800-876-1172

globalw.com

- 7 -

Figure 2

VI. Operation

a. The microwave rod antenna is stimulated by an electromagnetic pulse

transmitter and sends very short pulses to a target. The pulses reflect from

the target and then they are received back by the same antenna. The

electrical signal from the antenna is amplified and processed. The distance

to an object is calculated and then converted to 4-20 mA. Optionally, level

information is also sent to a PC via RS232 or RS485 for diagnostic data

logging and programmable set-up.

b. Turning the low dielectric materials operation mode ON or OFF:

The ON mode is recommended to eliminate multiple reflections in tanks

and for materials with a dielectric constant lower than 4. To turn the low

dielectric materials mode ON, push the calibration button and hold until the

LED light flashes yellow, then red, and then turns off. Release the button.

The blinking green LED light indicates that the low dielectric materials

mode is ON. To turn the low dielectric materials mode OFF, push the

calibration button and hold until the LED light flashes yellow, then red, then

turns off. Release the button. The constant green LED light indicates that

the low dielectric materials mode is OFF. The low dielectric materials

operation can also be turned ON or OFF with the Radar Level Transmitter

software during PC communications, which is recommended.

Advertising