Serial Interface – Quick Reference
COM2 Port Settings
Baud
rate:
115200
Data
bits:
8
Parity:
None
Stop
bits:
1
Flow
control:
None
Login Procedure
From the Login: prompt, type config followed by the <enter> key.
When prompted for a password type config followed by the <enter> key.
The following menu will then appear.
Network Port 1 Network Port 2
============== ==============
1. Boot method: static [dhcp] 11. Boot method: static [dhcp]
2. address: 192.168.0.18 12. address: 192.168.1.18
3. netmask: 255.255.255.0 13. netmask: 255.255.255.0
4. gateway: 192.168.0.1
5. broadcast: 192.168.0.255 15. broadcast: 192.168.1.255
6. mtu: 1500 16. mtu: 1500
7. controller ip: 192.168.0.18
8. controller port: 5432 18. webserver port: 80
9. Exit
Type the menu option number required followed by the <enter> key.
Where required, type the new value followed by the <enter> key.
To exit the menu and return to the main command prompt type 9 <enter>
Command Options
The following commands are also supported from the main command prompt:
Exit
to logout from the session
Reboot
to force the VN-MATRIX device to restart
Ping
to test network communications with another device (see page 127).