www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Set up and operation

Y

E

F

C

2

D

2

F

Fig. 7 Circulation cooling system (option)

C

2

Cooling water inlet G

3

/

4

D

2

Cooling water outlet G

3

/

4

E

Cooling air inlet

F

Cooling air outlet

Y Display

The cooling circuit is fi tted with thermostat-control-
led three-way valves. This enables diversion of water
past the heat exchanger during the pump start-up
phase. During operation of the pump, a temperature
switch monitors the water temperature and a fl ow
switch controls the fl ow rate. The cooling system is
equipped with a temperature and fl ow switch.

Weight / operating weight

101 / 131 kg

Tank capacity

30 l

Further detailed technical data on request

The Operating Instructions for this cooling sys-

tem is enclosed on the device.

4.4.2 Circulation cooling (option)