Elmo Rietschle S-VSI 100(01)/300(01)/300(12) User Manual

Page 27

Advertising
background image

27

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Maintenance and repair

M

M

I

1

K

1

H

1

K

H

I

7.2.1 Changing the oil

7.2.1 Ölwechsel

Fig. 8 Changing the oil

H, H

1

Oil fi lling point

I, I

1

Oil sight glass

K, K

1

Oil discharge point

M

Oil recommendation plate

NOTICE

Always change the oil when the machine is at
operating temperature and in an atmospherically
ventilated area.
If it is not completely emptied the amount that can
be refi lled is reduced.

The waste oil must be disposed of in compliance with
the local environmental protection regulations.
If you change the type of oil, empty the oil tank
completely.

The oil level in the sight glasses (Fig. 8/I, I

1

) must be

checked every month.
When refi lling with oil the machine must be switched
off and vented to atmospheric pressure. With clean
operations the oil must be changed after every
7,500 operating hours.
The oil viscosity must comply with ISO VG 150 as
per DIN 51519.
Designation as per DIN 51502: CLP HC 150.
GEAR-LUBE 150 or equivalent oils by other manu-
facturers (also see oil recommendation plate (Fig. 8/
M)).

Advertising