Elmo Rietschle S-VSI 100(01)/300(01)/300(12) User Manual

Page 34

Advertising
background image

34

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Final pressure (max.
vacuum) is not
reached

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated

Section 7.2

Too little cooling water

Note cooling water consump-
tion

Section 9

The mesh fi lter is dirty

Clean or replace the mesh
fi lter

Section 7.2.2
Section 7.4

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean the cooling ribs

Section 7.2

The cooling water system is
obstructed

Check the cooling water sys-
tem and the pipes

Section 7.2

Too little cooling water

Note cooling water consump-
tion

Section 9

Cooling water infl ow is too hot

Note the max. intake tem-
perature

Section 9

The machine makes
a abnormal noise

Deposits on the rotors

Clean the working space and
the rotors

Elmo Rietschle
Service

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

Advertising