Elmo Rietschle S-VSI 100(01)/300(01)/300(12) User Manual
Page 20
![background image](/manuals/316149/20/background.png)
20
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Installation
5.4
Connecting the cooling water pipe
NOTICE
Cooling water control!
The vacuum pump must not be operated without
cooling water control.
Danger breakdown of the pump
Ensure that the cooling water stream is not inter-
rupted.
a) Connect the cooling water pipe to the cool-
ing water inlet (Fig. 2/C, 3/C) and the cool-
ing water discharge pipe to the cooling water
outlet (Fig. 2/D, 3/D).
NOTICE
Only use
pH-neutral,
clean and fi ltered water
for cooling
Dirt particles and aggressive water may lead to
malfunctions or to premature wear in the cooling
system
Suitable cooling water
see Info “Recommended water quality”, Page 4
NOTICE
The cooling water operating pressure must not
exceed 6 bar
Cooling water temperature must be between
15 - 50 °C.