Installation

5.5

Filling with lubricating oil

a) Fill the lubricating oil (for suitable sorts see

„Maintenance“) for the gear teeth and the bear-
ings into the oil fi lling points (Fig. 2/H, 2/H

1

) up

to the middle of the inspection glasses (Fig. 2/
I, 2/I

1

).

b) Close the oil fi lling points.

5.6 Connecting

the

motor

DANGER

Danger of death if the electrical installation has
not been done professionally!
The electrical installation may only be done by a spe-
cialist electrician observing EN 60204. The operating
company has to provide the main switch.

a) The motor‘s electrical data is given on the data

plate (Fig. 2/N) or on the motor data plate (Fig. 2/
P

1

). The motors comply with DIN EN 60034

and are in protection class IP 55 and insulation
class F. The appropriate connection diagram is
located in the motor‘s terminal box (not for the
plug connection version). The motor data must
be compared with the data of the existing mains
network (current type, voltage, network frequen-
cy, permitted current value).

b) Connect the motor via the plug connection or

the motor protection switch (for safety reasons,
a motor protection switch is required and the
connecting cable must be installed via a cable
fi tting to provide strain relief).
We recommend using motor protection switches
with delayed switch off, depending on possible
excess current. Temporary excess current may
occur when the machine is started cold.

NOTICE

Power supply
The conditions at the installation location must match
the information on the motor data plate.
Without derating the following is permissible:

• ± 5% Voltage deviation
• ± 2% Frequency deviation