www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Maintenance and repair

7

Maintenance and repair

DANGER

Danger of death from touching live parts.
Before maintenance work disconnect the machine
by pressing the main switch or unplugging it and
ensure that it cannot be turned on again.

WARNING

Hot surfaces and equipment
During maintenance work there is the danger of
getting burnt on hot components (Fig. 2, 3/Q) and
by the machine lubricating oil.
Wait for the machine to cool down.

7.1 Ensuring

operational

safety

Regular maintenance work must be carried out in order to ensure operational safety.

Maintenance intervals also depend on the operational demands on the machine.

With any work observe the safety instructions described in Section 2.8 “Safety notes for installation, com-
missioning and maintenance”.

The whole unit should always be kept in a clean condition.

7.2 Maintenance

work

Interval

Maintenance to be carried out

Section

monthly

Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.

monthly

Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.

monthly

Clean the ventilation slots and the cooling ribs on the ma-
chine.

at least once a year

Check for coupling wear

7.2.1

depending on how dirty the
discharged medium is

Clean the protection mesh

7.2.2

weekly / daily

Check the oil level and the sealing oil

7.2.3

5.000 h

Changing the oil

Sealing oil degrades rapidly

Changing of the shaft sealing rings and the shaft wearing
sleeve

7.2.4