www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Maintenance and repair

s

6

n

1

n

2

n

5

n

4

n

3

s

4

s

2

s

3

7.2.4 Changing of the shaft sealing rings and the shaft wearing sleeve

Fig. 12 Changing of the shaft sealing rings and the

shaft wearing sleeve VWP 500 - 1500

Switch off the pumps and vent to atmospheric pres-
sure.
After unscrewing the allen screws (Fig. 10, 11/s

1

) pull

off the motor together with the motor side coupling
half (Fig. 10, 11/q) and suspend with the lifting de-
vice.

VWP 500 - 1500
After unscrewing the screws (Fig. 10/s

5

) remove the motor fl ange (Fig. 10/n). Unscrew countersunk screw

(Fig. 12/s

2

) and remove with disc (Fig. 12/s

3

). Pull off the coupling driven (Fig. 10/q

1

) with a suitable puller.

Remove key (Fig. 12/s

5

). Drain the oil in the chamber on the motor side by unscrewing the plug (K

1

). After

unscrewing the allen screws (Fig. 12/s

6

) lever out the intermediate fl ange (Fig. 12/n

1

) in the area of the fi xing

pin. The splash plate (Fig. 12/n

2

) must have a vertical position with their recess, otherwise it is impossible

to remove the intermediate fl ange. Remove wearing sleeve (Fig. 12/n

3

) of the piston and change it. Push

off sealing rings (Fig. 12/n

4

) resp. (Fig. 12/n

5

) with a drift from the motor side out of the intermediate fl ange

(Fig. 12/n

1

) and change them.

Re-assemble in reverse order.

NOTICE

For fi lling the sealing oil chamber with oil remove
the ventilation screw (Fig. 2/G

1

).

VWP 500 - 1500

Advertising