Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Pre-pump does
not reach ultimate
vacuum

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

Sealing oil degrades
rapidly

Sealing rings and the wear-
ing sleeve of the shaft
feedthrough are worn out

Change sealing rings and the
wearing sleeve of the shaft
feedthrough

Section 7.2.4

The machine makes
a abnormal noise

Deposits on the rotary piston

Clean the working space and
the rotary piston

Elmo Rietschle
Service

The coupling rubbers are
worn

Replace coupling rubbers

Section 7.2.1

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.