5.1

Testing the Battery Backup Time

This test measures how long the batteries can provide backup power by having them power the
loads until they are discharged.

Tips:

•

This test should be done once a year when the batteries are new. When the batteries are

three years old or older, it should be done once every six months.

•

This test should be done when new loads are connected to the unit.

•

The unit should have been in Line Present mode for 24 hours before starting this test so

the batteries are fully charged.

•

Do a self test (Section 3.3) first. If it passes then do this test. If it doesn’t find out why

before proceeding.

•

For reference, compare your measured time to the times listed in Section 5.6, “Battery

Run Times.” Because of various factors, your time may not match the times listed.

Procedure:

1

Switch off the Input circuit breaker.

The display panel’s Line Failure LED turns on showing the unit is
operating on backup battery power.

Record this start time.

2

The Low Battery Warning LED turns on.

Record this time.

3

The run time is the time between

1

and

2

.

4

Switch on the Input circuit breaker.

The unit runs on line power and starts charging the batteries.

Battery Backup Time Test Finished