2.4 Lectro ZTT/ZTT+ Power Supplies

Installation Procedure:
1. Remove the EDH4 transponder and cabling hardware from its shipping package.

2. Insert the 16-pin connector of the EDH4 Power Supply Interface Cable into the transponder’s PWR

SUPPLY interface port.

3. Install the EDH4 into the power supply cabinet using the adhesive fasteners on the bottom of the

transponder. Refer to Figure 2-9 for a possible mounting location in the enclosure.

4. Insert the power supply interface cable into the status monitoring connector of the power supply

(see Fig. 2-10). See the power supply manufacturer’s operating manual for information on the power

supply.

Required Materials

RF Cable

Customer supplied

Power Suppy Interface

Alpha p/n 875-335-22 (All ZTT and ZTT+ models)

Battery Sense Wire Harness for:

36V single string, 6', Alpha p/n 874-842-21
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 9', Alpha p/n 874-842-28

Battery Heater Mat Control Cable

Alpha p/n 875-627-20

Ethernet Cable (optional)

Alpha p/n 875-734-19

External Temperature Probe (optional)

Alpha p/n 745-178-21

Vin Sense (optional)

Alpha p/n 875-493-21

Surge Protector Ground Block

Alpha p/n 162-028-10

Vout/lout Sense Harness

Alpha p/n 875-456-10

Tamper Wire Harness

Alpha p/n 875-494-20

In Line Lightning Arrestor w/pass thru (130V) L-G, L-N, N-G

Alpha p/n 162-046-10 (not compatible with 240V

circuits/receptacles)

Fig. 2-11, Installing the EDH4

Fig. 2-12, Lectro ZTT/ZTT+

Before beginning this installation, verify power is removed from the power supply. Installation

should be performed only by qualified service personnel.