5.

Transport, storage and packaging

5.1

Transport

.

For transport to place of installation, use sturdy packaging.

.

Do not attach ropes or hooks to the handwheel for the purpose of lifting by
hoist.

.

If multi-turn actuator is mounted on valve, attach ropes or hooks for the pur-
pose of lifting by hoist to valve and not to multi-turn actuator.

Fitting the handwheel:

For transport purposes, handwheels from a diameter of 400 mm are supplied
separately.

Engage manual operation prior to mounting the handwheel! If
the manual operation is not engaged, damage can occur at the
change-over mechanism.

.

Engage manual operation (figure B-1):
Manually lift the red change-over lever while slightly turning the shaft back and
forth until manual operation engages. The manual operation is correctly
engaged if the change-over lever can be lifted by approx. 85°.

Manual force is sufficient for operating the change-over lever. It
is not necessary to use an extension. Excessive force may
damage the change-over mechanism.

.

Install handwheel over the red change-over lever on to the shaft (figure B-1).

.

Release change-over lever (should snap back into initial position by spring
action, figure B), if necessary, push it back manually.

.

Secure handwheel using the snapring supplied.

5.2

Storage

.

Store in well-ventilated, dry room.

.

Protect against floor dampness by storage on a shelf or on a wooden pallet.

.

Cover to protect against dust and dirt.

.

Apply suitable corrosion protection agent to uncoated surfaces.

If multi-turn actuators are to be stored for a long time (more than 6 months), the
following points must be observed additionally:

.

Prior to storage: Protect uncoated surfaces, in particular the output drive parts
and mounting surface, with long-term corrosion protection agent.

.

Check for corrosion approximately every 6 months. If first signs of corrosion
show, apply new corrosion protection.

After mounting, connect actuator immediately to electrical
system, so that the heater prevents condensation.

10

Multi-turn actuators SA 07.1 – SA 30.1/ SAR 07.1 – SAR 30.1
with actuator controls AUMA MATIC AM 01.1 / AM 02.1

Operation instructions

85°

Figure B-1

Figure B-2