Dialight HZC022501111312 SafeSite LED Area Light (GenI) User Manual

Page 3

Advertising
background image

Document No: 9100-127-1376-99 Rev A

Page 3 of 5

1501 Route 34 South, Farmingdale, NJ 07727

Tel: (732) 919-3119 Fax: (732) 571-5778 www.dialight.com

Wall mount

1) To secure the unit to the wall or mounting surface, use

3

/

8

” anchor bolts spaced for 6.75” (17.15cm) centers.


Pendant mount

1) Calculate and measure required conduit length. Refer to Figure 3 for reference dimensions.

2) Remove the 1” NPT plug(s) using a ½” drive ratchet.

3) Connect conduit to the NPT threads on the junction box. If using top conduit entrance, secure and tighten the set

screw.


Stanchion mount

1) Refer to additional instructions included with adapter plate.


Wiring

1) Remove the front cover of the splice box cover using a

3

/

16

” hex driver.

2) Insert cables, allowing ample wire for splicing.

3) Connect the two internal flying leads, line to black and neutral to white, using twist-on wire nuts.

4) Connect the ground wire to the grounding screw.

5) Replace the splice box cover. To maintain seal, make sure that the o-ring is still present and properly seated

in the groove. Make sure that the screws are tightened completely.

Figure 1.