4.1 Lightning Protection

The Beacon incorporates protection against voltage surges (as induced by nearby
lightning strikes) by means of Gas Discharge Tubes (GDT’s).



Section 5: Maintenance and Troubleshooting

No regularly scheduled maintenance is required for the Beacon.

1-

Dialight warranties the light output of the Beacon to meet or exceed FAA
requirements for 5 years period (See Section 8, Dialight Warranty Statement).
LED Module replacement after 5 years is recommended to ensure FAA
compliance.

2-

General cleaning of the Dome Assembly is recommended after re-lamping with
regular glass cleaning solution, soapy water or any acrylic cleaning solutions. No
other cleaning solutions are recommended. Abrasive compounds will scratch the
Dome Assembly.


Table 1 Lists possible faults and repair procedures for the L-264 Beacon

Table 1 Troubleshooting

Symptom

Possible Cause

Corrective Action

Beacon does not light

No DC power


Damaged LED Module



Failed Power supply

Verify proper DC levels from
power source thru supply lines.

Replace defective LED Module.
See repair and replacement
procedures.

Replace power supply

Beacon does not flash

Refer to controller
documentation supplied
by the manufacturer.