Orientation

The ADR may be installed in one of the 24 possible mounting orientations that align with the primary axes of the
vehicle.

The 24 mounting orientations are defined in the following table.

LEDs face

back

LEDs face

front

LEDs face

up

LEDs face

down

LEDs face

left

LEDs face

right

Connector faces back

X X X X

Connector faces front

X X X X

Connector faces up

X X X X

Connector faces down

X X X X

Connector faces left

X X X X

Connector faces right

X X X X

Figure 8 – Example Mounting Orientation (connector faces back, LEDs face up)

The readings from the three axes of the accelerometer are always aligned to a default vehicle orientation.

+Z

+Y

+X

Figure 9 – Default Vehicle Orientation

Notes:
• All references to the X, Y and Z axes in triggering setup, and logging and CAN outputs, refer to the default vehicle

orientation.

• The installed orientation must be specified using the Device Configuration function; see the

General Tab

section