SOLUTION STEPS: You will need another person to complete these steps.

1. Using a wrench, LOOSEN the four 5/16 carriage bolts that hold the motor and motor bracket in
place. DO NOT REMOVE these bolts.


2. Use a 2x4 as a wedge and a 4x4 as a fulcrum.


3. Stand in front of the machine and pull the 2x4 towards your body in order to create enough tension
on the belt. Do this while someone else tightens the four carriage bolts.


4. Once the bolts are tight, test the belt tension through the rear of the machine again and drill a set of
test holes.

5. Repeat these steps, if necessary, until there is enough tension on the belt.




Revised 2/9/2007