23.80

Power loss during drill cycle


If the machine is experiencing power loss during the drill cycle the following items will need to be
checked. If either is found to exist, it is possible that the amperage of the machine is falling too low to
allow proper operation of the machine.

SOLUTION STEPS:

1. If you are running the machine off of an extension cord, it must be AT LEAST 14 ga. and it must
be no longer than 6 feet.

2. If you are running the machine off of a power strip, make sure that the machine is not the last in
the line of plugs AND that nothing else on the strip has a large simultaneous amperage draw.

3. Check that the felt oiler is charged with oil so that the head is meeting with as little resistance as
possible.





















Revised 2/9/2007