Advertising

I 0147 -
10
I 0147 -
11
11
GB
GB
(keep ALU pressed)
6.2.2 - Wheels with weights inside (alu-s)
Measure the dimensions according to the scheme given below:
SEQUENCE:
a) To change
aI press
b) To change
aE press
c) To change
dI press
d) To change
dE press
N.B.: dE by default = 0.8 dI
N.B. When dI is reselected, the system automatically sets dE = 0.8 dI.
The system automatically calculates the distance between the centres of gravity of the weights by
considering them approx. 14 mm wide. To display the unbalance regarding the preset dimensions, press
button
; if a spin has already been made, the system automatically recalculates the unbalance;
otherwise press the
push button for a new spin.