9 - Self-calibration

9.1 - Wheel balancer

For self-calibration of the machine, proceed as follows:

- Fit a medium-sized wheel with steel rim on the shaft. Example: 6" x 14" (± 1")

- Preset the exact dimensions of the wheel mounted.

CAUTION!! Presetting of incorrect dimensions would mean that the machine is not correctly calibrated, therefore

all subsequent measurements will be incorrect until a new self-calibration is performed with the correct

dimensions!

until the positioning LED’s

change from flashing into

steady.

- It is highly important to

avoid the wheel from

being knocked during

this spin.

- Add a 100 gram weight

(3.5 oz) on the outside in

any angular position.

-

MACHINE CALIBRATED

- Remove the reference

weight and balance the

wheel as described pre-

viously.

The values derived by the machine from the self-calibration cycle are automatically memorized in a special memory

which retains them even when the machine is switched off. Hence each time the machine is switched on again, it is

ready for correct operation. However, the self-calibration operation can be repeated whenever required or if there is
some doubt as to the correct operation of the machine.

9.2 - Automatic rim distance gauge

Press:

Shift the distance gauge to position “0” and keeping it quite still, press:

Shift the distance gauge to position “15” and keeping it quite still, press:

CORRECT CALIBRATION

- Return the gauge to rest position
- The wheel balancer is ready for operation

N.B.

In the event of errors or faulty operation, the writing

CAL P.O

appears on the display: shift the gauge

to position

0

and repeat the calibration operation exactly as described above. If the error persists, contact

the Technical Service Department. In the event of incorrect input in the rim distance gauge calibration

function, press

to cancel it.

- Hold down keys

- Press

- Press