GB

3 - COMMISSIONING

3.1 - Anchoring

The machine can be operated on any fl at non-resilient fl oor.
Make sure that the machine rests solely on the three support points provided (fi g. 2a).
If possible, it is advisable to anchor to the fl oor using relative mounting feet (see fi g. 2a) in the event of continual use
with wheels weighing over 35 Kg.

3.2 - Electrical connection

The machine is supplied with a single phase mains cable plus earth (ground).
The supply voltage (and mains frequency) is given on the machine nameplate. It may NOT be changed.
Connection to the mains should always be made by expert personnel.
The machine should not be started up without proper earth (ground) connection.
Connection to the mains should be through a slow acting safety switch rated at 4A amp (230V) or 10 amp (115V) .

3.3 - Adapter mounting

The balancing machine is supplied complete with cone adapter for fastening wheels with central bore. Other optional
fl anges can be mounted once the terminal part is removed (also see enclosed brochures)

DISMOUNTING THREADED END PIECE

N.B. : CAREFULLY CLEAN THE COUPLING SURFACES BEFORE PERFORMING ANY
OPERATION.

a) Back-off screw B and remove threaded end-piece A.
b) Fit the new adapter.