Table 128: time base id – ALLIED Vision Technologies Guppy PRO F-503 User Manual

Page 247

Advertising
background image

Configuration of the camera

Guppy PRO Technical Manual V4.0.0

245

The ExpOffset field specifies the camera specific exposure time offset in
microseconds (µs). This time (which should be equivalent to

Table 61: Cam-

era-specific exposure time offset

on page 154) has to be added to the expo-

sure time (set by any shutter register) to compute the real exposure time.

The ExpOffset field might be zero for some cameras: this has to be assumed
as an unknown exposure time offset (according to former software versions).

Note

Time base can only be changed when the camera is in idle
state and becomes active only after setting the shutter value.

ID

Time base in µs

0

1

1

2

2

5

3

10

4

20

Default value

5

50

6

100

7

200

8

500

9

1000

Table 128: Time base ID

Note

The ABSOLUTE VALUE CSR register, introduced in IIDC V1.3, is
not implemented.

Advertising