The ExpOffset field specifies the camera specific exposure time offset in
microseconds (µs). This time (which should be equivalent to
era-specific exposure time offset
on page 154) has to be added to the expo-
sure time (set by any shutter register) to compute the real exposure time.
The ExpOffset field might be zero for some cameras: this has to be assumed
as an unknown exposure time offset (according to former software versions).
Note
Time base can only be changed when the camera is in idle
state and becomes active only after setting the shutter value.
ID
Time base in µs
0
1
1
2
2
5
3
10
4
20
Default value
5
50
6
100
7
200
8
500
9
1000
Table 128: Time base ID