Sensor position accuracy of AVT Manta cameras

Method of positioning

Optical alignment of the photo sensitive sensor area into the camera front mod-
ule (lens mount front flange).

Reference points

Sensor: center of the pixel area (photo sensitive cells).
Camera: Center of the camera front flange (outer case edges).

Accuracy

x/y: +/- 150 μm (sensor shift)

z: +0 μm to -150 μm (optical back focal length)

α: +/- 0.5° (sensor rotation)

Figure 83: AVT sensor position accuracy

Note

x/y - tolerances between the C-Mount hole and the pixel area