Optical flange focal distance – ALLIED Vision Technologies Prosilica GC2450 User Manual
Page 45

Prosilica GC Technical Manual V2.0.8
45
Camera dimensions
Optical flange focal distance
Optical flange focal distance is the optical distance from the mounting flange to
the image sensor die (see figure 32 and table 18). Optical flange focal distance
can be calculated as:
Figure 32: Cross section of typical Prosilica GC assembly with C-Mount
Camera
Mount
Maximum Lens
protrusion [mm]
IR cut filter*
[mm]
Sensor window
[mm]
Nominal Flange focal
distance [mm]
GC650
C-Mount
13.64
0.00
0.75
17.78
GC650C
C-Mount
9.01
1.00
0.75
18.11
GC655
C-Mount
13.64
0.00
0.75
17.78
GC655C
C-Mount
8.29
1.00
0.75
18.11
GC660
C-Mount
13.64
0.00
0.75
17.78
GC660C
C-Mount
11.01
1.00
0.75
18.11
GC750
CS-Mount
9.12
0.00
0.40
12.63
GC750C
CS-Mount
3.84
1.00
0.40
12.97
GC780
C-Mount
13.64
0.00
0.75
17.78
GC780C
C-Mount
8.29
1.00
0.75
18.11
GC1020
C-Mount
13.64
0.00
0.75
17.78
GC1020C
C-Mount
9.01
1.00
0.75
18.11
Table 18: Flange focal distance and maximum lens protrusion for Prosilica GC cameras
Optical flange focal distance Flange focal distance
IR cut filter thickness
Sensor window thickness
+
3
-------------------------------------------------------------------------------------------------------------
–
Sensor window thickness
IR cut filter thickness
Max. lens protrusion
Flange focal distance
Section A-A
A
A
Image sensor die