Prosilica GC Technical Manual V2.0.8

45

Camera dimensions

Optical flange focal distance

Optical flange focal distance is the optical distance from the mounting flange to
the image sensor die (see figure 32 and table 18). Optical flange focal distance
can be calculated as:

Figure 32: Cross section of typical Prosilica GC assembly with C-Mount

Camera

Mount

Maximum Lens

protrusion [mm]

IR cut filter*

[mm]

Sensor window

[mm]

Nominal Flange focal

distance [mm]

GC650

C-Mount

13.64

0.00

0.75

17.78

GC650C

C-Mount

9.01

1.00

0.75

18.11

GC655

C-Mount

13.64

0.00

0.75

17.78

GC655C

C-Mount

8.29

1.00

0.75

18.11

GC660

C-Mount

13.64

0.00

0.75

17.78

GC660C

C-Mount

11.01

1.00

0.75

18.11

GC750

CS-Mount

9.12

0.00

0.40

12.63

GC750C

CS-Mount

3.84

1.00

0.40

12.97

GC780

C-Mount

13.64

0.00

0.75

17.78

GC780C

C-Mount

8.29

1.00

0.75

18.11

GC1020

C-Mount

13.64

0.00

0.75

17.78

GC1020C

C-Mount

9.01

1.00

0.75

18.11

Table 18: Flange focal distance and maximum lens protrusion for Prosilica GC cameras

Optical flange focal distance Flange focal distance

IR cut filter thickness

Sensor window thickness

+

3

-------------------------------------------------------------------------------------------------------------

Sensor window thickness

IR cut filter thickness

Max. lens protrusion

Flange focal distance

Section A-A