Out 1 – opto-isolated, Out 2– non-isolated, Signal ground – ALLIED Vision Technologies Prosilica GC2450 User Manual
Page 53: Video iris, Reserved

Prosilica GC Technical Manual V2.0.8
53
Camera interfaces
Out 1 – opto-isolated
Out 1 signal is optically isolated and requires a user voltage with a suitable pull
up resistor. Tie signal ground to Isolated IO GND to complete the external cir-
cuit. See
Camera I/O opto-isolated user circuit example
for wiring information.
Out 2– non-isolated
Out 2 signal is not electrically isolated and can be used when environmental
electrical noise is inconsequential and faster trigger response is required. Use
Signal GND to complete the external circuit. The output signal is a low voltage
TTL, maximum 3.3 V. Not suitable for driving loads in excess of 24 mA. See
Camera I/O non-isolated user circuit example
for wiring information.
Signal ground
Signal Ground must be connected to the user’s external circuit ground if In 2 or
Out 2 is to be used, or if the RS-232 port is to be used. Note that Signal Ground
is common with Camera GND; however, it is good practice to provide a separate
ground connection for power and signal.
Video iris
This signal can be used to drive the video input of a video iris lens. See
section for wiring information.
Reserved
These signals are reserved for future use and should be left disconnected.