Auto Page C3-RS1100 User Manual

Page 28

Advertising
background image

C3 RS1100REV. A

28

b. Press

button on the transmitter to set proper “Start Timer”. The chirp & LED

pause will confirm entry. (Increase “Start Timer ” is necessary.)

c.

Repeat steps 1 – 4.

Timer Checking Type

1. Turn the Ignition 'switch ‘ ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times and hold it on the 11

th

push until five chirps with a

long chirp is hearing then release the valet switch.

3. Press the transmitter

and

buttons at the same time to set the “Timer

Checking Type”. [3] LED flashes , [3] chirps to confirm this setting

Once you complete step 3, you can adjust and test “Start Timer” as below:

START TIMER PROGRAMMING: (TEST and ADJUST)

While the system is in Start Feature “E” programming mode,

1. Press the

button once on the transmitter to start the vehicle.

2. If everything goes well:

a. Press the '

button once on the transmitter to stop engine running. You have

been completed this programming successfully.

b.

Press

button on the transmitter to exit the program mode. There will be 3 long

chirps & 3 parking light flashes for confirmation.

3. If the crank time is too long, (Engine already successfully running, but still cranks):

a. Press the

button once on the transmitter to stop engine running.

b. Press the

button on the transmitter to set proper “Start Timer”. The chirp & LED

pause will confirm entry. (Decrease “Start Timer” is necessary.)

c. Repeat the step1 – 4.

4. If the crank time is too short, (Engine not running, crank stopped before starting):

a. Press the

button once on the transmitter to stop engine running.

b. Press

button on the transmitter to set proper “Start Timer”. The chirp & LED

pause will confirm entry. (Increase “Start Timer ” is necessary.)

c.

Repeat the step1 – 4.

TEST MODE

In this test mode, this system can test the Zone 2 (Instant ground trigger), the Zone 3
(Door trigger), and the Zone 1 & Zone 4 (2 stage shock sensor) sensitivity. The
installer can save time to test the 2-stage shock sensor sensitivity and sensor without
using the traditional arming/disarming procedures to test the sensors.
Enter:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times (holding in on the 11

th

) until five chirps with one long

chirp is heard then release the valet switch. You are now in the Start feature ‘”E”
programming mode.

a. Test the Zone 2 / Instant Ground Trigger & Zone 3 / Door Trigger:

Press and release the transmitter

and

buttons at the same time once. [1]

LED flash, [1] siren/horn chirp to indicate your are in Zone 2 / instant ground
trigger and Zone 3 / Door trigger test mode.

Trigger sensor

Siren chirps

Zone 2 / Instant Ground trigger (H6/17 Blue wire)

2

Zone 3 / Door trigger (H 6/15 Green or H6/19 Violet wire)

3