4 installation, 1 regulations, Installation – DE DIETRICH ROE-II _ ROE-H User Manual

Page 12

Advertising
background image

12

ROE-II / ROE-H

13/01/2011 - 300019360-001-I

4 Installation

4.1 Regulations



Installation and maintenance of the appliance must be
done by a qualified professional in accordance with
prevailing statutory texts and codes of practice.

Choose a location away from prevailing winds.

Units located outside are a source of noise. Ensure that they are in
the optimum position with regard to your neighbours:

- No not locate the outside unit close to where people sleep.
- Do not locate the unit opposite a wall with windows.
- Avoid placing it close to a terrace, etc..

In some cases, additional precautions are necessary owing to the
fact, for example, of too short a distance between you and your
neighbours.
When installing a noise reduction screen, respect the following
recommendations:
Locate the noise reduction screen as close as possible to the noise
source whilst allowing for the free circulation of air in the exchanger
on the outside unit and maintenance work.



No obstacles should hinder the free circulation of air on
the air exchanger (intake and output).

Place the outside unit on a base (concrete base frame, sill,
concrete blocks, etc.) with no rigid connection with the building
served
in order to prevent any transmission of vibrations. Ensure
sufficient above ground elevation (100 to 150 mm) to keep it above
water.
For regions where heavy snowfalls occur, raise this above ground
protection by at least 200 mm compared with the average depth of
the covering of snow.

C00034

2

Advertising