Legend – DE DIETRICH ROE-II _ ROE-H User Manual

Page 21

Advertising
background image

21

13/01/2011 - 300019360-001-I

ROE-II / ROE-H

ROE-II / ROE-H Heat Pump with an interior hydraulic module with additional electric heating
+ Circuit separation kit + 1 Buffer tank 150 litres + 1 direct circuit (underfloor heating) + domestic hot water by mixed 300-litre tank for heat pump

„

Legend

3.

3-bar safety valve

4.

Pressure gauge

7.

Automatic air vent

8.

Manual bleed valve

9.

Isolating valve

11.

Boiler pump

13.

Flush valve

16.

Expansion vessel

17.

Drain cock

18.

Heating circuit filling valve

21.

Outside sensor

22.

Boiler sensor

23.

Mixing valve outlet temperature sensor

24.

DHW tank heat exchanger primary inlet

25.

DHW tank heat exchanger primary outlet

26.

DHW load pump

27.

Anti-thermosiphon valve

28.

Domestic cold water inlet

29.

Pressure reducer

30.

Safety unit set at 7 bar

33.

Domestic hot water temperature sensor

34.

Primary pump

35.

Disconnecting cylinder

44.

65 °C safety thermostat with manual reset for heated floor (France:
DTU 65.8, DTU 65.14)

51.

Thermostatic valve

50.

Disconnector

56.

Domestic hot water circulation loop

57.

Domestic hot water outlet

(a)

Outside clock

64.

direct heating circuit (example: radiators)

65.

heating circuit with mixing valve; heating circuit which may be at low
temperature (heated floor or radiators)

89.

Heat transfer fluid container

112a. Solar sensor probe
112b. Domestic hot water sensor: Solar hot water tank
114

Primary solar circuit filling and draining device ( propylene glycol)

115.

Thermostatic distribution valve for each zone

126.

Solar regulator

129.

Duo-Tube

130.

Manual bleed degasser (Airstop)

131.

Flat or tubular solar panel

132.

Complete solar station with solar regulator

133.

Interactive remote control

145.

Fan convector

147

Filter

M000949-C