Changing the settings, Parameter descriptions, 3 changing the settings – DE DIETRICH TWINEO EGC 25 User Manual

Page 16

Advertising
background image

The current values can be read as follows:
1. Press the two f keys simultaneously. The symbol Q flashes.
2. Confirm using key S. 5t is displayed, alternating with the

current status 3 (for example).

3. Press the [+] key. 5v is displayed, alternating with the current

sub-status 30 (for example).

4. Press the [+] key. t1 is displayed, alternating with the current

flow temperature 60°C (for example).

5. Press the [+] key successively to scroll down the various

parameters. t", t3, t4, t5, t6.

6. Press the [+] key. 5p is displayed, alternating with the internal

set point 88°C (for example).

7. Press the [+] key. fl is displayed, alternating with the current

ionization current 70 µA (for example).

8. Press the [+] key. Mf is displayed, alternating with the current

fan rotation speed 3000 rpm (for example).

9. Press the [+] key. pr is displayed, alternating with the current

water pressure #0 bar (for example). If no water pressure sensor

is connected, [-.-] appears on the display.

10.Press the [+] key. p; is displayed, alternating with the current

modulation percentage 78 % (for example).

11.Press the [+] key. The readout cycle starts again with 5t.
12.Press the j key 2 times to return to the current operating mode.