Faults (type code exx), 2 faults (type code exx) – DE DIETRICH TWINEO EGC 25 User Manual

Page 25

Advertising
background image

Code

Description

Checking / solution

Su:31

The TAS is in open circuit

The Titan Active System® is on an open circuit

4

Contact the professional who takes care of maintenance of the

appliance

Remarks:

Domestic hot water production is stopped but may nevertheless be

restarted for 72 hours after the boiler is switched off.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler, check that

the TAS simulation connector is fitted to the SCU-s191 PCB.

Su:32

The TAS is short circuited

The Titan Active System® is short-circuited

4

Contact the professional who takes care of maintenance of the

appliance

Remarks:

Domestic hot water production is stopped but may nevertheless be

restarted for 72 hours after the boiler is switched off.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler, check that

the TAS simulation connector is fitted to the SCU-s191 PCB.

Su:33

The header sensor in the solar control

system is defective

Bad connection

Sensor fault

4

Contact the professional who takes care of maintenance of the

appliance

Su:34

The sensor in the solar tank is defective Bad connection

Sensor fault

4

Contact the professional who takes care of maintenance of the

appliance

6.2

Faults (type code Exx)

In the event of an operating fault, the control panel flashes and

displays a code.
1. Make a note of the code displayed.

The code is important for the correct and rapid diagnosis of the

type of failure and for any technical assistance that may be

needed.

2. Press the t key. If the code is displayed again, switch off the boiler

and then switch it back on.

Code

Cause of
the fault

Description

Checking / solution

e00

PCU

PSU PCB not connected

Bad connection

PSU PCB faulty

4

Contact the professional who takes care of maintenance of the

appliance

e01

PCU

The safety parameters are

incorrect

Bad connection

PSU PCB faulty

4

Contact the professional who takes care of maintenance of the

appliance

e02

PCU

The boiler flow sensor has short-

circuited

Bad connection

Sensor fault

4

Contact the professional who takes care of maintenance of the

appliance

EGC 25

6. Troubleshooting

03/12/2013 - 300026082-001-02

24