Code

Description

Checking / solution

Su:10
Su:11

The BL inlet on the PCU PCB terminal

block is open

The contact connected to the BL inlet is open

4

Contact the professional who takes care of maintenance of the

appliance

Parameter error

4

Contact the professional who takes care of maintenance of the

appliance

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

Su:13

Communication error with the SCU

PCB

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

SCU PCB not installed in the boiler

4

Contact the professional who takes care of maintenance of the

appliance

Su:14

The water pressure is lower than 0,8

bar

Not enough water in the circuit

4

Top up the installation with water

Su:15

Gas pressure too low

Incorrect setting of the gas pressure switch on the SCU PCB

4

Check that the gas valve is fully opened

4

Contact the professional who takes care of maintenance of the

appliance

Su:16

The SU PCB is not recognised

Wrong SU PCB for this boiler

4

Contact the professional who takes care of maintenance of the

appliance

Su:17

The parameters saved on the PCU

PCB are impaired

Parameter error on the PCU PCB

4

Contact the professional who takes care of maintenance of the

appliance

Su:18

The PSU PCB is not recognised

Wrong PSU PCB for this boiler

4

Contact the professional who takes care of maintenance of the

appliance

Su:19

The boiler has not been configured

The PSU PCB has been changed

4

Contact the professional who takes care of maintenance of the

appliance

Su:21

Communication error between the

PCU and SU PCBs

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

Su:22

No flame during operation

No ionization current

4

Check that the gas valve is fully opened

4

Contact the professional who takes care of maintenance of the

appliance

Su:25

Internal error on the SU PCB

4

Contact the professional who takes care of maintenance of the

appliance

Su:28

An HL tank is detected whilst the boiler

cannot control it.

This message disappears after 10

seconds if the boiler can control the

HL tank

4

Wait for 10 seconds to see whether the error persists

4

Contact the professional who takes care of maintenance of the

appliance

Su:29

Communication error between the

PCU and SCU-s191 PCBs

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

Su:30

Communication error between the

SCU-s191 PCBs and the solar control

system

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

6. Troubleshooting