6 Troubleshooting

6.1

Error messages (Sub-status

9)

To display the current error code, proceed as follows:
1. Press the two f keys simultaneously. The symbol Q flashes.
2. Confirm using key S. 5t is displayed, alternating with the

current status 3 (for example).

3. Press the [+] key. The display shows 5v and the current error

value (30, for example) alternately.

Code

Description

Checking / solution

Su:00

The PSU PCB is incorrectly configured Parameter error on the PSU PCB

4

Contact the professional who takes care of maintenance of the

appliance

Su:01

Maximum flow temperature exceeded The water flow in the installation is insufficient

4

Check the circulation (direction, pump, valves)

Su:02

The increase in flow temperature has

exceeded its maximum limit

The water flow in the installation is insufficient

4

Check the circulation (direction, pump, valves)

4

Check the water pressure

Sensor error

4

Contact the professional who takes care of maintenance of the

appliance

Su:07

Maximum difference between the flow

and return temperature exceeded

The water flow in the installation is insufficient

4

Check the circulation (direction, pump, valves)

4

Check the water pressure

Sensor error

4

Contact the professional who takes care of maintenance of the

appliance

Su:08

The RL inlet on the PCU PCB terminal

block is open

Parameter error

4

Contact the professional who takes care of maintenance of the

appliance

Bad connection

4

Contact the professional who takes care of maintenance of the

appliance

Su:09

Live/neutral inversion

Parameter error

4

Contact the professional who takes care of maintenance of the

appliance

M002722-A

EGC 25

6. Troubleshooting

03/12/2013 - 300026082-001-02

22