ETV System Server Software - User’s Guide Page

87

 

Alert Settings Tab

Alarm Settings Tab










Enable Alarm Check

to enable the alarm.

Trigger alarm if


Opens the Video Analytics Alert Settings window that allows you
to schedule the alarm recording period and configure alerts. The
Video Analytics Alert Settings window is the same as the Video
Motion Alarm Advanced Settings Window. See the section on
Video Motion Alarm Advanced Settings
for configuration information.

object stay

more than

Set the amount of time an object must be within the specified area before an alarm is triggered.

Alarm Dwell The

number of seconds of video recorded in alarm mode once the alarm is triggered.

Enable this option to reset the statistics to zero once the alarm is triggered.

Reset Statistics

when Alarmed

Due to the nature of the data gathered, disabling the Reset Statistics When Alarmed
feature can cause a flood of notifications when the threshold is reached. Please refer to the
Tripwire Rule Reset Statistics when Alarmed section for a graph visualising the potential
flood of notifications.

Time in Queue, Directional Exit Rule

The Time in Queue, Directional Exit Rule tracks how long a customer spends within a defined region in the cameras field of
view as long as they exit the region in a specific direction. The time will be tracked from the moment the customer enters
the region until they exit the region if they cross a defined Tripwire when exiting. This works well for application such as
tracking how long a customer spends in line before getting to a cashier.

In this Example shot, only customers that exit the defined region and

cross the tripwire in front of the cashiers at the bottom of the image will

be counted. This eliminates false information being generated by people

passing through the region but not waiting in line.

Advertising