1-3

Models SLA5810 and SLA5820

Section 1 Introduction

Installation and Operation Manual
X-PR-SLA5800-PC-eng
Part Number: 541B091AAG
July, 2010

Leak Integrity
Inboard to Outboard: 1x10

-9

atm scc/sec Helium max.

Helium leak test performed without fittings
Maximum Fluid Operating Temperature
0°C to 65°C (32°F to 149°F)
Ambient Temperature Limits
Operating: 0°C to 60°C (32°F to 140°F)
Non-operating: -25°C to 100°C (-13°F to 212°F)

PHYSICAL:

Materials of Construction
Wetted parts - stainless steel
Viton

®

fluoroelastomers

Optional:
Buna-N
Kalrez

®

Teflon

®

/Kalrez

Outline Dimensions
Refer to Figures 1-3 to 1-5

Process Connections
Refer to Figures 1-3 to 1-5

ELECTRICAL CHARACTERISTICS:
Electrical Connections
Analog option: 15-pin D-Connector, male (See Figure 1-1)
Digital I/O:

DeviceNet: 5-pin Micro-Connector, male
F

OUNDATION

Fieldbus:

one 4-Pin M8 connector for power and
one 4-Pin M12 connector for communications

Power Supply Voltage
Analog option:

+15 Vdc, ±5% (traditional -15 Vdc pin is ignored) or

+24 Vdc ±5%

Digital I/O:

DeviceNet I/O: 11-25 Vdc
F

OUNDATION

Fieldbus I/O: 14-27 Vdc

Power Requirements:

Watts, typical Watts, max.

Analog I/O option, no valve:

1.6

1.8

Analog I/O option, with valve:

3.6

4.0

Digital I/O option, n.v.:

3.6

4.0

Digital I/O option, w.v.:

6.9

7.6