Installation and operation manual – Brooks Instrument MT3809E User Manual

Page 10

Advertising
background image

1-4

Section 1 Introduction

Models MT 3809 & 3819

Installation and Operation Manual

X-VA-MT3809-3819-eng

Part Number: 541B049AHG

September, 2008

Table 1-1B Model MT 3819 (Tefzel Lined) Capacities and Pressure Drop

Table 1-1A Model MT 3809 Capacities, Pressure Drop and Viscosity Immunity Ceiling

CONNECTION SIZE

FLOAT MATERIAL STAINLESS STEEL 316L

METER

DIN

ANSI

FLOAT

WATER

AIR

1,2

Press Drop Press Drop VIC (cSt)

Max. Visc

PED

SIZE

DN mm

inches

CODE

l/h

gpm

scfm

nm3/h

mbar

inches WC

(cSt)

(cSt)

Category

15

1/2"

A

25

0.11

0.49

0.78

30

13

1

40

SEP

B*

65

0.28

1.2

2

30

13

1

20

SEP

C

130

0.59

2.4

3.7

30

13

1

120

SEP

D*

200

0.88

3.7

5.8

35

15

1

20

SEP

15

1/2"

A

250

1.1

5.2

8.2

45

19

2

250

SEP

B

400

1.7

7.7

12

55

23

1

180

SEP

C

650

2.8

11

18

60

25

2

475

SEP

D

1000

4.4

21

33

130

53

1.5

250

SEP

25

1"

A

1200

5.2

19

30

60

25

5

475

CAT I, II or III

B

1500

6.6

31

49

70

29

1.5

400

CAT I, II or III

C

2400

10

41

65

85

35

7

475

CAT I, II or III

D

3500

15

65

100

155

63

4

475

CAT I, II or III

40

1 1/2"

A

4000

17

67

100

50

21

50

475

CAT I, II or III

B

6000

26

94

140

60

25

30

475

CAT I, II or III

C

8000

35

150

230

150

61

2

475

CAT I, II or III

D

10000

46

210

330

300

121

2

475

CAT I, II or III

50

2"

A

6500

28

100

160

50

21

50

475

CAT I, II or III

B

9500

41

160

250

60

25

50

475

CAT I, II or III

C

12000

55

200

310

100

41

2.5

475

CAT I, II or III

D

20000

88

390

620

300

121

1

475

CAT I, II or III

80

3"

A

20000

88

390

620

110

45

8

475

CAT I, II or III

B

30000

130

550

860

140

57

7

475

CAT I, II or III

C

40000

170

750

1100

280

113

5

475

CAT I, II or III

100

4"

A

49000

210

NA

NA

160

65

15

475

CAT I, II or III

B

70000

300

NA

NA

210

85

10

475

CAT I, II or III

C

100000

440

NA

NA

300

121

5

475

CAT I, II or III

1. Air flows in scfm are given at 70°F and 14.7 psia
2. Air flows in nm3/h are given at 0°C and 1.013 bar (a)
3. *Minimum operating pressure required 7 psig / 0.48 bar

13

15

16

7

8

10

12

CONNECTION SIZE

TUBE

STANDARD FLOAT MATERIAL CAPACITIES (See Note 3)

METER

DIN

ANSI

FLOAT

WATER

AIR

1,2,4

Press Drop Press Drop

PED

SIZE

DN mm

inches

CODE

l/h

gpm

scfm

nm3/h

mbar

inches WC

Category

15

1/2"

GA

110

0.48

2

3.2

25

11

SEP

GB

170

0.75

3.2

5

50

21

SEP

15

1/2"

A

250

1.1

4.6

7.3

30

13

SEP

B

420

1.8

7.7

12

45

19

SEP

C

500

2.2

9.2

14

40

17

SEP

D

850

3.7

15

24

130

53

SEP

25

1"

A

1400

6.2

26

41

45

19

CAT I, II or III

B

2000

8.8

37

58

106

43

CAT I, II or III

C

2400

10

44

70

90

37

CAT I, II or III

D

3000

13

55

87

130

53

CAT I, II or III

40

1 1/2"

A

3000

13

55

87

50

21

CAT I, II or III

B

4000

18

74

110

75

31

CAT I, II or III

C

5000

22

92

140

85

35

CAT I, II or III

D

6000

26

110

170

120

49

CAT I, II or III

50

2"

A

6000

26

110

170

95

39

CAT I, II or III

B

8000

35

147

230

125

51

CAT I, II or III

C

12000

53

220

340

200

81

CAT I, II or III

D

15000

66

270

430

225

91

CAT I, II or III

1. Air flows in scfm are given at 70°F and 14.7 psia
2. Air flows in nm3/h are given at 0°C and 1.013 bar (a)
3. Sizes 7 & 8 floats are Hastelloy C-276 (Density = 8.94 kg/dm

3

), Sizes 10, 12 & 13 are PVDF (Density = 4.22 kg/dm

3

)

4. For gas applications operating pressure must be greater than 29 PSIA / 2 bar (a)

13

7

8

10

12

Advertising