Brooks Instrument MT3809E User Manual

Page 63

Advertising
background image

4-9

Section 4 Maintenance

Models MT 3809 and 3819

Installation and Operation Manual

X-VA-MT3809-3819-eng
Part Number: 541B049AHG
September, 2008

support.

e. Place the switch on the bracket with the open end facing towards the

center of the scale plate and the wires facing away from the scale
plate.

f.

Place the switch screw through the opening in the switch, and the

support bracket. Use the nut to secure the screw and tighten.

g. Plug in the switches.

h. Replace the scale and tighten two clamping screws. Make sure that

the alarm switch wires do not interfere with the alarm cam. Insure
that the pointer is aligned with the ‘R’ or zero mark. If not refer to
Section 4-3, Indicator Reference Mark (Zero) Adjustment.

Sizes 7 & 8

Sizes 10, 12 & 13

Figure 4-4 Meter Float Replacement & Cleaning (MT 3819)