Alliance Laundry Systems PHM1397C User Manual

Page 14

Advertising
background image

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Specifications and Dimensions

F8112101

12

Table 1 (continued)

Models

Specifications

40H

60H

80H

100H

125H

140H

175H

Water Inlet

Connection Size

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

1-1/4 NPT

1-1/4 NPT

Number of Inlets,
(std/opt)

2/3

2/3

2/3

2/3

2/3

2/3

2/3

Chemical Supply System

Number of Dry
Chemical
Compartments,
(std/opt)

1/5

1/5

1/5

1/5

1/5

1/5

1/5

Number of Liquid
Supply Connections,
(std/opt)

6/12

6/12

6/12

6/12

6/12

6/12

6/12

Cylinder Speeds/Centrifugal Force Data

Possible Wash Speeds,
RPM (G-Force)

10-60

(0.05-1.4)

10-60

(0.04-1.6)

10-60

(0.05-1.9)

10-60

(0.05-1.9)

10-55

(0.06-1.9)

10-55

(0.06-1.9)

10-55

(0.06-1.9)

Preset Wash Speed,
RPM (G-Force)

46

(0.8)

43

(0.8)

39

(0.8)

39

(0.8)

36

(0.8)

36

(0.8)

36

(0.8)

Balance Speed,
RPM (G-Force)

81

(2.5)

75

(2.5)

69

(2.5)

69

(2.5)

69

(2.5)

64

(2.5)

64

(2.5)

Preset Low Extract
Speed, RPM (G-Force)

511

(100)

477

(100)

437

(100)

437

(100)

405

(100)

405

(100)

405

(100)

Preset Medium Extract
Speed, RPM (G-Force)

605

(140)

564

(140)

516

(140)

516

(140)

479

(140)

479

(140)

479

(140)

Preset High Extract
Speed, RPM (G-Force)

775

(230)

723

(230)

662

(230)

662

(230)

573

(200)

573

(200)

573

(200)

Maximum SmartSpin
Speed, RPM (G-Force)

885

(300)

826

(300)

756

(300)

756

(300)

701

(300)

640

(250)

640

(250)

Drive Train Information

Number of Motors In
Drive Train

1

1

1

1

1

1

1

Drive Motor Power,
hp (kW)

3

(2.3)

5

(3.7)

7.5

(5.6)

7.5

(5.6)

10

(7.5)

7.5

(5.6)

15

(11.2)

Balance Detection

Vibration Switch
Installed

STD

STD

STD

STD

STD

STD

STD

Electrical Heating (Optional)

Total Electrical Heating
Capacity, kW

21.5@240V
21.5@480V

32.2@240V
21.5@480V

32.2@240V
21.5@480V

32.2@240V
21.5@480V

Not

Applicable

Not

Applicable

Not

Applicable

Number of Electrical
Heating Elements

6 – 240V
6 – 480V

9 – 240V
6 – 480V

9 – 240V
6 – 480V

9 – 240V
6 – 480V

Not

Applicable

Not

Applicable

Not

Applicable

Electrical Heating
Element Size, kW

3

3

3

3

Not

Applicable

Not

Applicable

Not

Applicable

Table 1

All specifications are subject to change without notification.