Specifications and Dimensions

41

F8112101

Pocket Hardmount

Electrical Specifications

Voltage Designation

Standard

Electric Heat

Mo

del

Co

de

Vo

lt

a

g

e

Cy

cl

e

Phase

Wir

e

Full Lo

ad

Amp

s

Br

eak

er

AW

G

mm

2

Full Lo

ad

Amp

s

Br

eak

er

AW

G

mm

2

40H

N

380 – 480

50/60

3

3

4

15

14

2.5

29

35

8

10

Q

200 – 240

50/60

3

3

8

15

14

2.5

56

60

6

16

X

200 – 240

50/60

1/3

2/3

11

15

14

2.5

56

60

6

16

60H

N

380 – 480

50/60

3

3

6

15

14

2.5

29

35

8

10

Q

200 – 240

50/60

3

3

11

15

14

2.5

84

90

3

25

X

200 – 240

50/60

1/3

2/3

12

15

14

2.5

84

90

3

25

80H

N

380 – 480

50/60

3

3

8

15

14

2.5

31

35

8

10

Q

200 – 240

50/60

3

3

15

20

12

4

87

110

2

35

100H

N

380 – 480

50/60

3

3

8

15

14

2.5

32

40

8

10

Q

200 – 240

50/60

3

3

15

20

12

4

88

110

2

35

125H

N

380 – 480

50/60

3

3

10

15

14

2.5

Not Available

Q

200 – 240

50/60

3

3

19

30

10

6

140H

N

380 – 480

50/60

3

3

11

15

14

2.5

Not Available

Q

200 – 240

50/60

3

3

20

30

10

6

175H

N

380 – 480

50/60

3

3

15

20

12

4

Not Available

40M

N

380 – 480

50/60

3

3

3

15

14

2.5

29

35

8

10

Q

200 – 240

50/60

3

3

5

15

14

2.5

56

60

6

16

X

200 – 240

50/60

1/3

2/3

9

15

14

2.5

56

60

6

16

60M

N

380 – 480

50/60

3

3

5

15

14

2.5

29

35

8

10

Q

200 – 240

50/60

3

3

9

15

14

2.5

84

90

3

25

X

200 – 240

50/60

1/3

2/3

11

15

14

2.5

84

90

3

25

80M

N

380 – 480

50/60

3

3

6

15

14

2.5

31

35

8

10

Q

200 – 240

50/60

3

3

11

15

14

2.5

87

110

2

35

100M

N

380 – 480

50/60

3

3

7

15

14

2.5

32

40

8

10

Q

200 – 240

50/60

3

3

12

15

14

2.5

88

110

2

35

140M

N

380 – 480

50/60

3

3

8

15

14

2.5

Not Available

Q

200 – 240

50/60

3

3

16

20

12

4

NOTE: Wire-size based on: NFPA 70 (NEC), Table 310.16, 75°C Column. No more than three current carrying
conductors per raceway. Use copper conductors only. Use circuit breakers only. Do not use fuses. Suggested breaker
size based on NFPA 70, Section 240.6. Contact local authority having jurisdiction for additional information. Local
electrical codes supersede all suggestions of this table. Follow all local electrical codes. Local is defined as place of
machine installation.